A Searle s experiment a wire of diameter d 0 060 cm is used
Last updated: 6/21/2023
![A Searle s experiment a wire of diameter d 0 060 cm is used](https://media.kunduz.com/media/sug-question-candidate/20211219091009146988-3216591.jpg?h=512)
A Searle s experiment a wire of diameter d 0 060 cm is used to find its young s modulus The length of given wire is L 200 cm and when weight of mass m 30 0 Es used in experiment extension in the length of wire was found to be 0 200 cm Then choose the correct option s Maximum permissible error in young s modulus of wire is 4 66 Maximum permissible error in young s modulus of wire is 3 The least count of the instrument by which length of the wire is to be measured is 1 cm The least count of the instrument by which diameter of the wire is to be measured is 0 001 cm